Conformarkby Peak Design
Articles
Software and control systems

Cybersecurity and control system requirements in the Machinery Regulation

What Annex III, sections 1.1.9 and 1.2.1 require for connections, safety software, logs and software versions, and how they relate to the Cyber Resilience Act and to harmonized standards.

6 min read24 November 2026Conformark by Peak Design

This article is for design engineers of machines with software, network ports, remote access or wireless control. Directive 2006/42/EC did not address attacks on a machine. Regulation (EU) 2023/1230 adds a new section 1.1.9, "Protection against corruption", to Annex III. It also extends section 1.2.1 on control systems. Both apply to machinery placed on the market from 20 January 2027.

The aim: safety, not general IT security

The Regulation addresses cybersecurity only where it affects safety. Recital 25 says that manufacturers must adopt proportionate measures, "limited to the protection of the safety" of the product. The same recital says that other Union acts on cybersecurity can also apply.

Section 1.1.9: protection against corruption

Section 1.1.9 has five requirements:

  1. A connection to another device, or to a remote device that communicates with the machine, must not lead to a hazardous situation.
  2. Some hardware components transmit signals or data and give access to safety-critical software. These components must have adequate protection against accidental or intentional corruption.
  3. Software and data that are critical for compliance with the essential health and safety requirements must be identified as such. They must have adequate protection against accidental or intentional corruption.
  4. The machine must identify the software installed on it that is necessary for safe operation. It must be able to give that information at all times, in an easily accessible form.
  5. The machine must collect evidence of a legitimate or illegitimate intervention in the installed software. This includes a modification of the software or of its configuration.

Requirement 2 also asks the machine to collect evidence of interventions in that hardware component.

Section 1.2.1: safety and reliability of control systems

Section 1.2.1 keeps the requirements of the Directive, such as the rules on faults, logic errors and unexpected start. It adds new points.

Control systems must withstand "reasonably foreseeable malicious attempts from third parties leading to a hazardous situation", where appropriate to the circumstances and the risks. The limits of the safety functions come from the risk assessment. Changes to settings or rules that could lead to a hazardous situation are not permitted.

The machine must enable a tracing log. The log covers data about an intervention. It also covers the versions of safety software uploaded after the machine is placed on the market or put into service. The log must stay available for five years after each upload. It serves only to show conformity, after a reasoned request from a competent national authority.

For control systems with fully or partially self-evolving behavior, there are more rules. The machine must not act outside its defined task and movement space. It must record data on the safety-related decisions of its safety software, and keep these data for one year. It must always be possible to correct the machine to keep it safe.

The last paragraph covers wireless control. A failure of the communication or connection, or a faulty connection, must not lead to a hazardous situation. Section 1.2.6 adds a related rule. An interruption, a return or a fluctuation of a communication network connection must not lead to a hazardous situation.

Logs and evidence of interventions

Sections 1.1.9 and 1.2.1 ask for three types of records:

  • evidence of interventions in the installed software, its configuration and the related hardware (section 1.1.9)
  • an identification of the installed safety software that the user can read at all times (section 1.1.9)
  • a tracing log of interventions and of uploaded safety software versions, kept for five years (section 1.2.1)

The Regulation does not specify a technical solution. Examples are a protected event log, a checksum of each safety program, and a version screen on the operator panel. Select the means from your risk assessment.

Software versions and the technical documentation

Article 10(3) and Annex IV, Part A, point (m) are related. On a reasoned request, the manufacturer must give the authority the source code or programming logic of the safety-related software. This applies if the authority needs it to check compliance. Keep each released version of the safety software, with its identification, in the technical documentation.

A software update after delivery can be a substantial modification under Article 3, point (16). The tracing log then shows what changed.

Relation to the Cyber Resilience Act

The Cyber Resilience Act, Regulation (EU) 2024/2847, sets cybersecurity requirements for products with digital elements. Its reporting obligations apply from 11 September 2026, and its main obligations apply from 11 December 2027. A connected machine can be in the scope of both Regulations.

The two acts have different aims. The Cyber Resilience Act protects the product and its data against cyber threats. Sections 1.1.9 and 1.2.1 protect persons against hazards from corruption or attacks. The recitals of the Cyber Resilience Act say that compliance with it can help to show compliance with these two sections. The Machinery Regulation does not give a presumption of conformity for compliance with the Cyber Resilience Act.

Article 20(9) of the Machinery Regulation gives a different presumption. Regulation (EU) 2019/881 sets up cybersecurity certification schemes. A machine certified under such a scheme, with its reference in the Official Journal, is presumed to conform to sections 1.1.9 and 1.2.1. This applies only as far as the certificate covers these requirements. We could not find a published scheme reference that covers machinery.

Harmonized standards status

At the time of writing, no list of harmonized standards under the Machinery Regulation is published. The Commission says that it prepares the first list. That list will include most of the standards now cited under the Directive. The Commission also says that it will clarify where a standard does not yet fully address a new or updated essential requirement.

Section 1.1.9 is new, so no standard written for the Directive had it as a target. Standards on industrial security, such as the IEC 62443 series, can help as a method. At the time of writing, no such standard gives a presumption of conformity under the Regulation.

The Commission has published temporary and partial sections of its guide to the Regulation. One section covers section 1.1.9 and points (a) and (f) of section 1.2.1. The Expert Group on Machinery endorsed it in a written procedure that ended on 5 November 2026.

What to do now

  1. List each interface of the machine: network ports, USB ports, wireless links, remote access and service tools.
  2. For each interface, add the hazards from corruption and from malicious attempts to the risk assessment.
  3. Identify the safety-critical software and data, and protect them against change.
  4. Show the identification of the installed safety software on the machine.
  5. Add a protected log of interventions, configuration changes and safety software uploads.
  6. Keep the tracing log for five years after each upload.
  7. Check the loss and the return of each wireless and network connection.
  8. Keep each released version of the safety software in the technical documentation.
  9. Check if the Cyber Resilience Act applies to the machine or to its components.
  10. Read the Commission guide section on sections 1.1.9 and 1.2.1.

Conformark adds the tasks for sections 1.1.9 and 1.2.1 to your checklist. It also adds a Cyber Resilience Act check when the machine connects to networks, apps or ports.